Oil analysis is an invaluable tool, but often misinterpreted

Oil1

I once read an article in a major boating magazine entitled “Oil Analysis Made Simple.” It caught my attention because, as a trained oil analyst, I know from experience as well as formal training that oil or fluid analysis is complex and fraught with both opportunity for sampling errors and misinterpretation of reports. It’s little wonder the science of oil analysis is frequently dismissed by industry professionals, especially brokers, as unreliable and a black art; in many cases, they have good reason to question the results.

In practice
Lubricating oil is the very lifeblood of an engine: Without it, gears and bearings would quickly overheat, seize and grind themselves to a halt. In addition to lubrication and heat removal, as oil courses through an engine it picks up and carries with it contaminants, from moisture and carbon to metal, coolant and fuel — all of which can be identified and analyzed. In doing so, and when carried out properly and accurately, this analysis can reveal a great deal about engines and other equipment. I frequently refer to this analysis as the mechanic’s (and boat owners’/buyers’) crystal ball.

The return on investment where fluid analysis is concerned can be substantial. Analyzing a few ounces of crankcase oil, for instance, can yield reams of information about the current health of an engine, and how it has been maintained throughout its life. For instance, sodium (typically but not always considered an external contaminant, as it is contained in some coolant mixtures), when found in an engine’s lubricating oil, may be indicative of ingestion of salt-laden mist. This can happen if spray is ingested into an engine room air intake. By contrast, wear metals such as iron, chrome, nickel, copper, lead, tin and aluminum each tell a different story about a component within the engine, from pistons and rings to bearings and valves.

Transmissions benefit from fluid analysis every bit as much as an engine.

The quantity of metal in a sample, for instance, measured in parts per million, when compared to the number of hours accrued by the sample oil determines whether there is cause for concern. Still, other contaminants such as diesel fuel and soot, and imbalances such as total base number and viscosity, can indicate malfunctioning fuel injection systems, use of the incorrect stock oil or simply oil that is old, worn out and acidified.

Fluid detective work doesn’t end with crankcase oil. Transmission and hydraulic fluid, as well as coolant, are also fertile ground for this sort of testing. Transmission fluid analysis can often detect issues with bearings and clutches, shift mechanism adjustment, damaged gears or overheating. Many transmissions include some type of coolant; however, if it’s not working properly, oil can overheat and lose some of its lubricating properties. Coolant includes additives that inhibit rust and corrosion as well as control pH; over time, however, these become depleted. Common wisdom dictates that marine diesel cooling systems should be flushed and coolant replaced every two years, but that’s likely conservative. An analysis of the coolant can stave off this service if it’s unnecessary, often paying for itself. The same is true of hydraulic fluid — if the system in which it’s used is working properly and not exposed to outside contaminants, it may remain serviceable for years and thousands of hours of run time.

These bearing parts came from a transmission whose oil indicated high levels of iron, prompting disassembly and discovery of a failed roller bearing assembly.

Common analysis errors
As valuable as fluid analysis is, it isn’t perfect — and when undertaken by a well-meaning but inexperienced do-it-yourselfer or pro alike, misinterpretation is all too easy. For example, a client once contacted me, distraught over the results of a transmission fluid analysis report. It showed very high levels of copper, so high that the analysis lab had flagged them in red. His mechanic suggested a rebuild. After exchanging a few emails with the transmission manufacturer, however, I determined that the clutches were sintered copper alloy, and therefore those high copper readings were not abnormal. The lesson here is that the value of the amount of data a lab has accumulated on an engine, transmission or other type of equipment is critically important when it comes to alerting the user whether there’s potential trouble or that all’s well.

Another all too common — perhaps the most common — error is one I refer to as “flag fixation,” wherein those reviewing oil analysis reports simply scan them for red, yellow and green flags, or indications of trouble, or the absence thereof. If no red or yellow flags are present, they pronounce the equipment from which the report was derived as healthy. This practice is both dangerous and, for industry professionals like mechanics and surveyors, irresponsible.

This fluid analysis report for a hydraulic system has copper flagged high — not unusual because the heat exchanger is copper, and often leaches metal into oil.

On one occasion, I reviewed an analysis report for a client, one the mechanic had passed with an “it’s all good,” thanks to the lack of red and yellow flags. Yet, when I scrutinized the figures, I realized that when completing the sample form he’d inadvertently reversed the lube time (the number of hours on the oil) with the unit time (the number of hours on the engine). As a result, the lab believed the oil had accrued nearly 800 hours, while the engine itself had only 150 — an impossibility, of course, yet the lab technician inputting the data failed to capture the discrepancy. The threshold for contamination for oil that has accumulated this many hours is extremely high, which failed to trigger a red flag. However, when the correct lube time was later inserted and the data re-run by the lab, the engine’s report went from green to red. Much like the old computer programming axiom “garbage in, garbage out,” oil analysis is only as good as the accuracy of the data supplied to the lab.

Yet another area where analysis often goes awry involves sampling technique. If, for example, a vacuum pump and hose are used to draw a sample, and the latter’s intake is dragged across the bottom of an oil pan in the process, it is likely to show elevated wear metal — material that has accumulated over the course of hundreds or thousands of hours (note that referencing the sample tube to the dipstick can prevent this sort of error). It is for this reason that many commercial users rely on sample valves installed in oil galleries, rather than vacuum pumps and tubes, when drawing crankcase oil samples. The valve delivers oil as it is circulating through the engine, offering the most accurate representation of its condition.

Whether you are taking samples yourself or relying on a professional, make certain good sampling technique is practiced, including avoidance of cross-contamination (vacuum tubes must never be reused). If a vacuum pump is being used, avoid splashing oil up into the pump, which is yet another source of cross-contamination, and label each bottle the moment it is capped to prevent mixing up the samples.

It’s best to mark containers the moment the sample is drawn.

I routinely hear, particularly from brokers, about the questionable validity of a single analysis as opposed to engines whose oil has been sampled regularly. While there is value to the interpretation of trends in oil analysis, single samples — especially where pre-purchase surveys are concerned — are both useful and valid. Don’t let anyone talk you out of them or dismiss the results, provided that the samples were taken properly, forms are accurate and reports reviewed carefully.

The ideal fluid analysis regimen includes crankcase oil with every change, in addition to coolant, transmission and hydraulic fluid annually. Regular analysis of this sort will pay dividends during your ownership, as well as when it comes time  to sell, as a record of regular analysis raises the confidence of any buyer.

For years a full-service yard manager, Steve D’Antonio now works with boat owners and buyers as Steve D’Antonio Marine Consulting (stevedmarine.com). He is an ABYC-certified Master Technician and sits on ABYC’s Hull and Piping and Drive Train Project Technical committees.

By Ocean Navigator